The Working Standard WS 2330 is a three-phase precision reference meter for electrical power and energy measurement dedicated to on-site meter testing. The device provides also function of local data exchange with smart meters (data readout).
Properties
- Handy and Lightweight Design with 5.7” Color Display
- Integrated Voltage Input 300 V CAT IV / 600 V CAT III Integrated Power Supply Function from Measured Circuit
- Two Universal Inputs for Voltage and Current Probes for Power or CT / VT Ratio, Phase and Burden measurement
- Accuracy Classes 0,2; 0,1; 0,05
- Color Graphic Display and Alphanumerical Keypad
- USB Connectivity with PC
- Enhanced Optical Scanning Head
- Optical Interface for Local Data Exchange with Smart Meters According to IEC 62056-21
- High Capacity Memory for Configuration and Data Storage
- LED and TTL Impulse Outputs with Programmable Meter Constant or Frequency
- Vector Diagram and Signal Shape Display (Oscilloscope Mode)
- Harmonics Analysis in Tabular and Graphical Format
- Database System for Tested Meters and Measured Results with Search Capabilities
- Fast Synchronization of Measured Data and Configuration with PC
- PC Software for MS Windows
- Configurable User Interface (Regional and Functional Modifications)
- Transport Case with High Protection Degree
Technical data
Basic Frequency Range | 40 ... 70 Hz | |
---|---|---|
Input Circuits | 1-phase 2-wires; 1-phase 3-wires and 2-phase; 3-phase 3-wire / 4-wire | |
Voltage Range | 0,1 ... 600 V phase to neutral | Manual or auto range |
Current Range | Depending on type of current sensor - up to 20 A / 120 A / 240 A / 6000 A or more | |
Power Factor Range | -1 ... 0 ... 1 | |
Phase Angle | 0 ... 360° | |
Basic Frequency Range | 40 ... 70 Hz | |
Bandwidth | up to 3000 Hz | |
Harmonics | up to 60th | |
Communication | USB interfaces (SCPI compatible comm. protocol); wireless (2,4 GHz) – Bluetooth; optical interface for communication with meters according to IEC 62056-21 (via OPTH 1200) | |
Display | 5,7” / 320 x 240 pixels / 256 colors | |
Memory for Data | min 1GB (>1000 load points) | |
Temperature coefficient | < 50 x 10-6 / °C | |
Operating Temperature | -20 ... +50 °C | |
Storage Temperature | -25 ... +60 °C | |
Operating Humidity | max. 95% relative humidity (non-condensing) | |
Power Supply | from int. rechargeable accumulators (Li-Ion); from Power Adapter (100 - 240 VAC / 12 VDC); from Car Outlet Adapter (12 VDC); from measured volt. circuit (30 - 300 V /45 - 65 Hz) |
|
Power Consumption |
from battery: 2 W (body only), 4 W (body + CC @ 100 A); PFMC: 5 W / 10 VA (body only), 7 W / 14 VA (body + CC @ 100 A) |
|
Applicable Standards | IEC 60736, IEC 62056-21, IEC 61010-2-032 | |
Degree of Protection | IP-42 (device); IP-67 (transport case) |
|
Safety Requirements | Isolation protection: EN 61010-1; category: 300 V CAT IV / 600 V CAT III | |
Dimensions | 220 x 160 x 60 mm (basic device); 464 x 366 x 176 mm (transport case) | |
Weight | basic device: 0,85 kg; total standard setup: 6,5 kg |