  • AMT B1x-SAxTE for active energy measuring, 1-rate, up to 100 A AMT B1x-SAxTE for active energy measuring, 1-rate, up to 100 A
    Three-phase static electricity meters AMT B1x-SxxTE are determined for single-rate active energy measurement in direct and indirect connection, displaying results on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio. The test pulses indicated by red LED are proportional to the consumed energy. Measurement „using an unidirectional mechanical register“ provides positive energy measurement even if the reverse energy flow.
  • AMT B1x-OxxTEI for active and reactive energy measuring, single- and double-rate, up to 100 A AMT B1x-OxxTEI for active and reactive energy measuring, single- and double-rate, up to 100 A
    Three-phase static electricity meters AMT B1x-OxxTEI are determined for direct and indirect measurement of active and reactive energy with measured consumption displaying on LCD. They are manufactured in single-rate and double-rate versions with external switching of rates. The measured values are stored into special registers according to the OBIS codes. They are displayed on LCD in cyclic or step mode. The data are stored in non-volatile memory during power outage. The performance of internal circuits is monitored during the operation of a meter and the statuses are stored in the particular registers. The content of registers can be displayed. The test pulses indicated by red LED are proportional to the consumed energy. The meters can be produced in version with measurement in summary mode (measurement „using an unidirectional mechanical register“) or with measurement in separation mode (measurement of “consumption – supply”).
  • AMT B1x-FxxTxIIxfor active and reactive energy, with RTC and communic., up to 100 A AMT B1x-FxxTxIIxfor active and reactive energy, with RTC and communic., up to 100 A
    Three-phase multifunctional static electricity meters AMT B1x-FxxTxIIx are determined for measurement of active and reactive electric energy, instantaneous active power for consumption and supply, maximum demand, voltage, current, and power factor in threephase four wires networks in direct or indirect connection. They enable measurement of energy in rates controlled by internal clock (up to 4 rates) or externally controlled in two rates. The measured values stored in registers according to the OBIS codes are displayed on LCD in cyclic or stepping mode. The data are stored in non-volatile memory during power outage. It is possible to check the data using back-up power supply during this time. The electricity meters can be parametrized and readout by using optical probe AMOS type and software supplied by the manufacturer. The testing pulses are signalling by a red LEDs separately for active and reactive energy. They could be equipped with communication interfaces RS 485 or Mesh module. The meters can be produced in version with measurement in summary mode (measurement „using an unidirectional mechanical register“) or with measurement in separation mode (measurement of “consumption – supply”).
  • AMT B2x-Fx (active and reactive en.), multirate, RTC, comm. modules, up to 65, 100 and 120 A AMT B2x-Fx (active and reactive en.), multirate, RTC, comm. modules, up to 65, 100 and 120 A
    Three-phase multifunctional static electricity meters AMT B2x-FxxTxIx are determined for measurement of active, reactive and apparent electric energy, instantaneous active, reactive and apparent power for consumption and supply, maximum demand for active, reactive and apparent energy, voltage, current and power factor in 3-phase 4-wires networks in direct and semidirect connection. They enable measurement of energy in rates controlled by internal clock (up to 4 rates) or externally controlled in two rates. The measured values stored into special registers according to the OBIS codes are displayed on LCD in cyclic or step mode. The electricity meters can be parametrized and readout by using optical probe AMOS type and software supplied by the manufacturer. The test pulses are indicated by red LEDs, they are proportional to the active and reactive consumed energy. Electricity meters can be produced in version with summary measuring mode (using a mechanical register) or in version with separate mode (measuring of consumption and supply).
  • AMT B3x-FA4SET for active energy, multirate, with RTC, up to 100 A AMT B3x-FA4SET for active energy, multirate, with RTC, up to 100 A
    Three-phase static electricity meters AMT B3x-FA4SET are determined for measurement of active energy, instantaneous active power for consumption and supply, voltage, current and power factor in 3-phase 4-wires network in direct connection. They enable measurement of energy in rates controlled by internal clock (up to 4 rates) or externally controlled in two rates. The measured values stored into special registers according to the OBIS codes are displayed on LCD in cyclic or step mode. The data are stored in non-volatile memory during power outage, which can be viewed on the LCD. The electricity meters can be parametrized and readout by using optical probe AMOS type and software supplied by the manufacturer. The testing pulses proportional to the consumed energy are signalling by a red LED. The meters can be produced in version with measurement in summary mode (measurement „using an unidirectional mechanical register“) or with measurement in separation mode (measurement of “consumption – supply”).
  • AMT B0x SA4T for DIN rail, for active energy measuring, with mechanical register, up to 65 A AMT B0x SA4T for DIN rail, for active energy measuring, with mechanical register, up to 65 A
    Three-phase static electricity meters AMT B0x-SA4T are determined for single-rate measurement of active energy in direct or indirect connection displaying value on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio. The test pulses indicated by red LED are proportional to the consumed energy. Measurement „using an unidirectional mechanical register“ provides positive energy measurement even if the reverse energy flow.
  • AMT B0x OA4T for DIN rail, for active energy measuring, with LCD, up to 65 A AMT B0x OA4T for DIN rail, for active energy measuring, with LCD, up to 65 A
    Three-phase static electricity meters AMT B0x-OA4T are determined for active energy in direct or indirect connection. They are produced in single-rate and double-rate version with external control of the rates. The measured values are stored in registers according to the OBIS codes are displayed on LCD in cyclic or stepping mode. The data are stored in non-volatile memory during power outage. The performance of internal circuits is monitored during the operation of the meter and the statuses are stored in the particular registers. The test pulses indicated by red LED are proportional to the consumed energy. The meters can be produced in version with measurement in summary mode (measurement „using an unidirectional mechanical register“) or with measurement in separation mode (measurement of “consumption – supply”).
  • AMT B0x FA4T for DIN rail, for active energy measuring, with LCD and RTC, up to 65 A AMT B0x FA4T for DIN rail, for active energy measuring, with LCD and RTC, up to 65 A
    Three-phase static electricity meters AMT B0x-FA4T are determined for single-rate and multi-rate measurement of the active energy in direct or indirect connection. The measured values are stored in registers according to the OBIS codes are displayed on LCD in cyclic or stepping mode. They enable to record of the selected energy registers contents (total registers and rates registers) and the maximum demands (MD) registers contents per billing period (max. 6 records). It is also possible to record number of power failure and reverse energy flow occurrences. They enable measurement of energy in rates controlled by internal clock (up to 4 rates) or externally controlled in two rates. The data are stored in non-volatile memory during power outage. The meters can be parametrized and readout using optical probe AMOS and softver AMsoft supplied by the manufacturer. The test pulses indicated by red LED are proportional to the consumed energy. The meters can be produced in version with measurement in summary mode (measurement „using an unidirectional mechanical register“) or with measurement in separation mode (measurement of “consumption – supply”).
  • AMT B0x-FxxTII for DIN rail, with RTC and communication, up to 65 A AMT B0x-FxxTII for DIN rail, with RTC and communication, up to 65 A
    Three-phase multifunctional static electricity meters AMT B0x-FxxTIIx are determined for measurement of active and reactive electric energy, instantaneous active power for consumption and supply, maximum demand, voltage, current and power factor in threephase four wires networks in diredct or indirect connection. They enable measurement of energy in rates controlled by internal clock (up to 4 rates) or externally controlled in two rates. The measured values stored in registers according to the OBIS codes are displayed on LCD in cyclic or stepping mode. The data are stored in non-volatile memory during power outage. The electricity meters can be parametrized and readout by using optical probe AMOS type and software supplied by the manufacturer. The test pulses indicated by red LED are proportional to the consumed energy.
  • Software for readout and parametrization AMsoft Software for readout and parametrization AMsoft
    The program is designed for static meters operation either with simple registers or with smart, programmable functions, performed by the ETD during their manufacturing (technological part) and through operational utilization of static meters. For programming there are used PCs (the ports COM, USB), where the optical head is connected for performance of serial two-way communication with ETD in accordance with IEC/EN 62056-21.
  • DTS-353 1L/1M/2M for DIN rail, for active energy measuring, 7-module case DTS-353 1L/1M/2M for DIN rail, for active energy measuring, 7-module case
    Electricity meters, type DTS-353 1L, DTS-353 1M and DTS-353 2M are simple and precise three-phase meters for active energy measurement. They are designed for secondary measurements of various appliances, offices and premises.
  • DTS-353 L4 for DIN rail, for active energy measuring, 4-module case DTS-353 L4 for DIN rail, for active energy measuring, 4-module case
    Electricity meters DTS-353 L4 are simple and precise three-phase meters for active energy measurement. Using internal battery allows displaying of measured energy on LCD also without connected power supply.